Skip to content

When something does not work

"Fix the red fields first" and Run does not start. Something in a form or a table is wrong. The window has switched to the tab with the problem; the red field says what it expects. The Messages tab lists every problem.

"The model had no 'invdyn' settings: they are switched on now with default values." Run was pressed for a part the robot does not have. The part is now switched on with a first guess. Check it, then press Run again.

Only some links move in an inverse dynamics run of a closed loop. The loop closed in a different assembly, usually because the motion starts far from the start pose, or in a pose the mechanism cannot reach. Start near the motor values shown on the Inverse dynamics form.

"loop closure did not converge: singular configuration or unreachable pose". The starting pose q0 of a closed loop cannot be closed. Use a pose the mechanism can reach, such as the one in the bundled model.

"... cannot be opened". The file is not valid YAML, or is not a model. The message gives the line and column of the first mistake. Choose Open in a text editor in the message (or YAML > Open in a text editor for a file that opened), fix the line, save, and open the file again or choose YAML > Reload from disk.

The Model tab shows "The model cannot be drawn". A cell of the links table could not be read (for example text where a number belongs). The message names it; the last good drawing stays.

The Lagrange multipliers plot is missing. Open chains have no multipliers; only closed loops do.

MP4 is not offered. ffmpeg is not installed or not on your PATH. GIF always works.

The window does not open on Linux and the message mentions the Qt platform plugin "xcb". Qt 6.5 and newer need one more system package on Ubuntu: sudo apt install libxcb-cursor0.

A large robot is slow. A large robot such as the Stewart platform takes some seconds instead of a fraction of one. Choosing ode15s as the solver helps a lot with stiff controllers.

I cannot see the toolbar buttons or the text is tiny. Use Larger in the toolbar, or a larger window (F11 for full screen).